Pemeliharaan Listrik yang diterapkan di sebuah perusahaan maupun industri merupakan salah satu prosedur untuk menjaga electrical system selalu terantisipasi keamanan dan keselamatannya.
The backbone of many electric power systems is the medium voltage
distribution system. Typically operating at voltages ranging from
2,400 to 34,500 Volts, voltage stress, corona, surges and protection
of equipment all create unique challenges in design, equipment
selection, operation and engineering. This 2 day class takes you
through the basics of medium voltage power systems including
components,equipment, design and operation problems as well as
protection of medium voltage systems.
Perlunya memilih provider training CASA TRAINING yang tepat agar pengetahuan kita mengenai ELECTRICAL MAINTENANCE LOW AND MEDIUM VOLTAGE tidak salah
TUJUAN TRAINING ONLINE ELECTRICAL MAINTENANCE LOW AND MEDIUM VOLTAGE
Setelah selesai mengikuti kursus Electrical Maintenance Low and Medium
Voltage ini, peserta diharapkan akan mengerti dan memahami masalah
Audit sampai pada penerapan konsep Power Management System. Dimana hal
itu diperlukan oleh perusahaan sebagai suatu komponen pendukung
kegiatan produksi untuk menjamin ketersediaan energi listrik dengan
efisien dan murah.
Dengan mengikuti pelatihan CASA TRAINING Peserta dapat berbagi pengetahuan / sharing knowledge mengenai ELECTRICAL MAINTENANCE LOW AND MEDIUM VOLTAGE dengan peserta dari perusahaan lain yang bergerak di bidang ELECTRICAL MAINTENANCE LOW AND MEDIUM VOLTAGE
MATERI TRAINING ONLINE ELECTRICAL MAINTENANCE LOW AND MEDIUM VOLTAGE
MEDIUM VOLTAGE SAFETY
- Electrocution at Low vs. Medium Voltage, Arc Flash,
- Qualified Person, Approach Boundaries
TYPES OF MEDIUM VOLTAGE SYSTEMS
- Utility and Industrial One lines, Reliability Requirements,
- Overhead and Underground Systems, Regulated Systems
MEDIUM VOLTAGE CABLE
- Copper vs. Aluminum Design, Voltage Ratings
- Insulation Ratings, 100%, 133%, 173% Insulation Levels,
- Shielding Requirements, Electric Fields, Terminating MV
- Conductors, Orientation of Overhead Lines
MEDIUM VOLTAGE SUBSTATION TRANSFORMERS
- Core and Coil Design, Aluminum and Copper Windings
- Tank Construction, Loss Evaluation, Efficiency, Regulation
SPOT NETWORKS
- Spot Network Design, Network Protectors, Network Protector
- Relay Operation, Directional Protection Requirements
PARTIAL DISCHARGE
- Corona, Surface Tracking, Voltage Stress, Sensing Partial
- Discharge, Component Failure
GROUNDING MEDIUM VOLTAGE SYSTEMS
- Resistance Grounding, Solid Grounding, Ungrounded Delta
- Charging Current, Effect of Ground Faults on Delta Voltage
SURGE PROTECTION
- Lightning and Switching Surges, Classes of Surge Arresters
- MCOV Ratings – (Maximum Continuous Operating Voltage)
- TOV – (Maximum Temporary Over Voltage Capability),
- Protective Characteristics, Surge Arrester Selection, Energy
- Capability, Effect of Grounding on Arrestor Selection,
- Insulation Coordination,
CURRENT TRANSFORMER APPLICATIONS
- Ratings, Selection Process, Accuracy, Saturation, Excitation
- Curves, Burden Calculation, Momentary Ratings
MEDIUM VOLTAGE CIRCUIT BREAKERS
- Vacuum, Air, Oil, SF6 Designs, Symmetrical Interrupting
- Rating, K-Rated Voltage Factor, Close and Latch Capability
RECLOSERS
- Application on Feeder Circuits, Recloser Settings
- Continuous Current and Interrupting Ratings
MEDIUM VOLTAGE FUSES
- Medium Voltage Switches, Load Rating, Close and Latch
- Rating, Short Time Rating, Expulsion vs. Current Limiting
- Fuse Characteristics, E and R Rated Fuses, Fuse Cutouts
MEDIUM VOLTAGE PROTECTION CONCEPTS
- Medium Voltage Protection, Relays, Circuit Breakers, R and
- E rated Fuses, Short Circuit vs. Overcurrent Protection
DISTRIBUTION FEEDER PROTECTION
- Protection with Fuses – 300%, Overcurrent Protection with
- Relays – 600%, Short Circuit Damage Characteristics, Relay
- “Reach” for End of Line Faults
ROTATING MACHINERY PROTECTION
- Requirements, Decrement Curves, Thermal Damage Curves,
- Reactive, Capability Curves, Differential Protection
MEDIUM VOLTAGE MOTOR CONTROLLERS
- Protection Requirements, Motor Management Relays, Circuit
- Breaker Protection, Relaying, Class R Rated Fuses
TRANSFORMER PROTECTION
- ANSI C57 Thru Fault Curves, Impact of Transformer Winding
- Configuration, Overview of Differential Protection, Inrush and
- Harmonic Restraint
Electrical Maintenance Low and Medium Voltage Training Audience
- D3 atau SLTA yang berpengalaman kerja minimal 3 tahun, dan atau setara.
- Teknisi, Operator dan Supervisor didalam bidang instrumentasi,
maintenance dan operasional. - Mereka yang dalam tugasnya berhubungan dan atau terkait dengan
materi kursus.
METODE
Metode penyelenggaraan baik secara training online atau training zoom atau training daring maupun training offline atau training tatap muka :
- Presentasi
- Diskusi antar peserta
- Studi kasus
- Simulasi
- Evaluasi
- Konsultasi dengan instruktur
TRAINER/ INSTRUKTUR
Instruktur yang berkompeten di bidang ELECTRICAL MAINTENANCE LOW AND MEDIUM VOLTAGE
Tim Instruktur CASA TRAINING
Kegiatan training dan konsultansi dikelola oleh para tenaga ahli dan instruktur yang berpengalaman dan berkompeten di bidangnya. Ini akan menjadi “kunci” bagi suksesnya aktivitas training dan konsultansi yang dijalankan.Juga menjadi kunci bagi perkembangan perusahaan anda di masa depan.
Karena kompleksnya pelatihan ini, maka dibutuhkan pendalaman yang lebih komprehensif melalui sebuah training.Dan menjadi sebuah kebutuhan akan training provider yang berpengalaman di bidangnya agar tidak membuat peserta menjadi cepat bosan dan jenuh dalam mendalami bidang teknik ini.
Jadwal Pelatihan Casa Training 2026 :
Batch 1 : 20 – 21 Januari 2026
Batch 2 : 10 – 11 Februari 2026
Batch 3 : 3 – 4 Maret 2026
Batch 4 : 14 – 15 April 2026
Batch 5 : 19 – 20 Mei 2026
Batch 6 : 24 – 25 Juni 2026
Batch 7 : 8 – 9 Juli 2026
Batch 8 : 19 – 20 Agustus 2026
Batch 9 : 16 – 17 September 2026
Batch 10 : 7 – 8 Oktober 2026
Batch 11 : 18 – 19 November 2026
Batch 12 : 9 – 10 Desember 2026
Lokasi Training Offline atau Online :
- Yogyakarta
- Jakarta
- Bandung
- Bali
- Surabaya
- Lombok
- Online via Zoom